TIHE 2024German Exhibitors tpm taberna pro medicum GmbH
tpm taberna pro medicum GmbH

tpm taberna pro medicum GmbH

Booth number: B25
www.tpm.eu

About us

tpm – taberna pro medicum - is manufacturing the world-wide best-in-class high frequency and high resolution ultrasound imaging system for the skin. Everything from one hand:  Development, manufacturing, maintenance, repair, sales and service.

The family business was founded in 1978 after more than 8 years of experience in sales and service of medical ultrasound equipment for ophthalmology. Since 2012 the company is managed by Sven Scharenberg in the second generation and is constantly developed further.

In 1998 we established a quality management system, today the DIN EN ISO 13485:2016.

Address

tpm taberna pro medicum GmbH
Steinweg 9
21335 Lüneburg
Germany

E-mail: info@tpm.eu
Phone:  +49 4131 401555
Internet: www.tpm.eu
Sadyk Azimov
3-d dead end, house 22
100047 Tashkent
Uzbekistan

E-mail: info@tpm.eu
Phone:  +99 890 9101410
Internet: www.tpm.eu

Contact person:

Eva Maria Scharenberg
Sales English/German
E-mail: e.scharenberg@tpm.eu
Phone: +494131401555

Dr. Nikita Bezugly
Sales Russian/English
E-mail: n.bezugly@tpm-online.de

Products & Services

Our product portfolio for High Frequency Ultrasound system offers frequencies from 18 MHz to 100 MHz mostly covered by portable DUB USB devices. This broad range of devices provides an resolution (axial) from 88 µm to 16 µm.

Founded in 1978 as manufacturer and distributor of
medical devices for dermatology and ophthalmology systems.

The finest resolution and superior quality of signal processing and image analysis are pre-eminent for the DUB systems. The DUB provides continuous and rapid high resolution ultrasonography to exacting scientists.

Latest we finalized a new development for measuring the ocular perfusion pressure and the ocular perfusion reserve.

DUB SkinScanner - High Frequency Ultrasound

High frequencies with one ultrasound imaging system.
for 18, 22, 33, 50 or 75 MHz applicators

Key features

Max. axial resolution: 21 µm at 75 MHz
Max. digitizing depth: 16 mm
Scan width: 12.8 mm linear (33 µm step width)
Medical CE and FDA 510K
Connection: USB 2.0 or USB 3.0
DUB SkinScanner software compatible
with all Windows operating systems

Viewing modes: B-Scan, RF-Mode, A-Scan,
Sum-A, ScanLoop (2000)
Filter: Hilbert transformation
7 color scales
Measurement: length, area, density, width,
depth, ROI, rectangular measuring field
Automatic skin thickness
Automatic epidermis thickness (50 and 75 MHz)
Automatic skin density
Personalizable: e.g. clinic or doctor‘s name
 
Available applicators
Linear B-Scan 18-22 MHz
Max. penetration/axial resolution: 15 mm / 72 µm

Linear B-Scan 22-28 MHz
Max. penetration/axial resolution: 10 mm / 57 µm

Linear B-Scan 33-38 MHz
Max. penetration/axial resolution: 6 mm / 42 µm

Linear B-Scan 50 MHz
Max. penetration/axial resolution: 4 mm / 31 µm
Linear B-Scan 75 MHz
Max. penetration/axial resolution: 3 mm / 21 µm

DUB SkinScanner75

OPFA - Ocular Pressure Blood Flow Analyzer

The newly developed Ocular Pressure Blood Flow Analyzer -OPFA- makes it possible to examine ocular circulation on both eyes simultaneously in a non-invasive, quick and reliable manner. The examination is easy to perform and well tolerated by the patient and requires no dilatation of the pupillae. It is an objective registration method with automatic analysis and evaluation and provides comprehensive data in form of print-outs and graphs.

Fields of application

  • Early detection and management of primary open angle glaucoma (POAG) resulting from impaired autoregulation

  • Early diagnosis and management of normal-tension glaucoma (NTG) resulting from reduced perfusion reserve

  • Identification of reduced autoregulatory capacity as a sign of transition from ocular hypertension (OH) to primary open angle glaucoma and initiation of an appropriate therapy

  • Determination of ocular perfusion pressures, ocular arterial pressures and ocular pulse blood volumes as the basis of glaucoma diagnosis and treatment control

  • Examination of ocular perfusion of retinal arterial and venous blockages, occlusion of the arteria ophthalmica or choroidal vascular abnormalities

  • Diagnosis and therapy control of arteriitis temporalis (Mb. Horton)

  • Assessment of ocular perfusion in supra-aortic arterial occlusion processes, pre- and post-operative

  • Monitoring of ocular perfusion in hereditary and degenerative retinal and choroidal diseases to evaluate progression

  • Ocular perfusion in age-related macula degeneration and macular dystrophie

  • Monitoring of ocular perfusion in diabetes and in diabetic retinopathies

  • Monitoring and management of ocular perfusion for patients with hypertony or hypotony and with vascular disregulation

Visit website

OPFA System with Laptop

Suction Cups

Result Curve

DUBcutis

The new entry level in high frequency ultrasound imaging systems.

Visit website

DUBcutis

My German Pavilion

  • Manage your personal profile here and enter your desired business contacts to German companies
  • Keep an eye on the trade fairs, German exhibitors and products that are of interest to you
  • Receive an e-mail notification on relevant upcoming German trade fair presentations
Sign up now